Real-time trace gas analyzer for Voc detection

Achieve real-time, multi-analyte detection of volatile organic compounds and gases, eliminating the need for chromatography steps while ensuring high sensitivity and selectivity across diverse applications.

Detects and Quantifies VOCs in Real-Time

The Syft Tracer from Syft Technologies revolutionizes trace gas analysis by providing real-time, selective detection and quantification of VOCs and inorganic gases without the need for chromatographic separation. Its capabilities make it indispensable across semiconductor, environmental, pharmaceutical, and consumer goods industries, offering unmatched analytical flexibility to tackle diverse application challenges, from semiconductor wafer quality assurance to ensuring air purity in cleanrooms. The Syft Tracer supports continuous, automated monitoring, seamlessly integrating into existing production lines with its high-throughput, 24/7 operation. Utilizing chemical ionization and an extensive compound library, it delivers trace-level sensitivity and high selectivity, all packaged in a user-friendly system requiring minimal sample preparation. Compliant with safety and environmental standards such as CE and ISO9001, the Syft Tracer is engineered for robustness, featuring a durable construction suited for demanding industrial environments. Customizable features and engineering support ensure optimal alignment with specific project needs, promoting efficient maintenance and longevity.

Benefits

  • Enhances efficiency with real-time gas analysis, eliminating the need for sample preparation.
  • Increases operational productivity through continuous, high-throughput monitoring.
  • Supports complex compound detection across diverse applications with its extensive ionization library.
  • Lowers operational costs with robust, low-maintenance design for 24/7 industrial use.
  • Ensures regulatory compliance with CE and ISO9001 certifications.

General


Applications
Industrial fumigation,Material emissions,Toxic industrial chemicals,Packaging testing,Odor analysis,Consumer goods,Voc emissions,Drug delivery devices,Semiconductors,Cleanroom monitoring,Environmental monitoring,Atmospheric research,Pharmaceuticals
End products
Chemical reagents,Plastic packaging,Air fresheners,Water quality sensors,Cleaning products,Industrial solvents,Respiratory inhalers,Food packaging,Semiconductor wafers,Air quality monitors,Building insulation,Cleanroom garments,Circuit boards,Construction materials,Perfumes,Microchips,Scented candles,Prescription medications,Adhesives,Aerosol canisters
Steps before
Sample collection,Sample transport,Source water preparation,Carrier gas preparation
Steps after
Data analysis,Report generation,Environmental monitoring,Sample disposal
Input ingredients
volatile organic compounds (VOCs),inorganic gases,small polar molecules,trace gases,residual solvents,airborne molecular contaminants (AMCs),contaminants,volatile emissions,odors,water and soil samples,trace fumigants,toxic industrial chemicals (TICs)
Output ingredients
real-time data analysis,multi-analyte detection,quantitative data,lab-grade results,analysis of contamination sites,broad-spectrum identification,characterization of odors and emissions
Market info
Syft Technologies is renowned for its advanced chemical analysis solutions, particularly using Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) for real-time, high-sensitivity detection of volatile organic compounds across various industries.

Technical Specifications


Detection type
Mass Spectrometry
Limit of detection
Compound specific,typical VOC <20 pptv
Compound coverage
1500+ compound library of VOCs and inorganics
Mass range
10 - 400 amu
Mass resolution
Unit resolution across the mass range
Linearity range
R2 > 0.99
Sample consumption
Typically,100 mL/min of scan
Performance Tune
Recommended daily,and per 5 °C change in ambient temperature since last run
Nitrogen carrier gas
>99.999% N2 at 160 mL/min while running scans
Helium carrier gas
>99.999% He at 360 mL/min while running scans
Source water bottle
DI Water at 200 mL per 6 months

Operating Characteristics


Real-time trace gas analysis
Low parts-per-trillion by volume (pptV)
Ease of operation
Push-button simplicity,no sample preparation
Changeover requirement
None,direct analysis
Multi-analyte detection
Simultaneous,in one analysis
Automation level
Manual / Auto operation
Continuous operation capability
24/7
System durability
Optimized for high-throughput environments
Performance tuning
Daily,per 5 °C change
Sample preparation
None required

Material Compatibility


Density/particle size
0.5–2.5 g/cm³ / 50–1000 µm

Physical Characteristics


Dimensions
Height (laptop and light tower flat)
Dimensions
Height (light tower at full extension)
Dimensions
Width
Dimensions
Depth
Weight
510 kg (1125 lb)

Custom Options


Control panel type
Push-button simplicity
User interface
User-friendly interface
Integration possibilities
24/7 operation optimized
System configuration
Single instrument configuration
Autosampler integration
High-throughput SIFT-MS analysis
Configuration flexibility
Unified configuration for multiple methods