High energy medical electron linear accelerator for radiotherapy
Optimize cancer treatment precision and efficiency with advanced radiotherapy technology designed for precise imaging, dynamic collimation, and seamless treatment delivery, ensuring tailored plans for each patient.

Delivers Precision Radiation for Cancer Treatment
The High Energy Medical Electron Linear Accelerator from Shinva Medical Instrument Co., Ltd. is engineered to improve the precision and efficiency of radiotherapy treatments. It provides comprehensive solutions for cancer therapy by delivering various X-ray energies (6MV, 10MV, 15MV) and electron rays (6 MeV to 21 MeV). Featuring a dual independent jaw collimator system and high-speed DMLC with 120 leaves, it ensures accurate targeting and optimization of treatment beams. The inclusion of IGRT treatment tables with auto-correction and real-time digital control enhances the sequencing and delivery of treatments, making it an ideal choice for hospitals, cancer treatment centers, and radiotherapy clinics. Supporting advanced protocols like 3D-CRT and SBRT, it integrates seamlessly into existing workflows with automation and control systems like KV-CBCT and EPID MV imaging. This system offers high-dose rate FFF mode, emphasizing operational efficiency while reducing radiation exposure. The equipment supports a range of medical applications from lung to head and neck cancer treatments, adaptable to develop custom oncology treatment protocols.
Benefits
- Enhances treatment precision, reducing patient risk and improving therapy outcomes.
- Automates delivery processes, minimizing human error and increasing operational efficiency.
- Integrates seamlessly with existing imaging systems to streamline workflow.
- Supports a wide range of treatment protocols, offering flexibility for personalized patient care.
- Reduces treatment time with high-dose rate modes, optimizing throughput in busy clinical settings.
- Applications
- Radiotherapy,Medical treatment,Healthcare equipment,Cancer therapy
- End products
- Oncology treatment protocols,Head and neck cancer treatment plans,Custom radiotherapy treatment plans,Breast cancer treatment plans,Prostate cancer treatment plans,Lung cancer treatment plans,Tumor imaging datasets
- Steps before
- Patient Positioning,Treatment Planning,CT Simulation
- Steps after
- Patient Monitoring,Image Processing,Dosimetry Review
- Input ingredients
- X-rays (6MV,10MV,15MV),multi electron rays (6 MeV to 21 MeV)
- Output ingredients
- high speed IMAT treatment delivery,KV-CBCT imaging,EPID MV imaging,3D-CRT support,SBRT support,high intensity FFF mode
- Market info
- Shinva is known for manufacturing medical equipment, including sterilization and disinfection devices, radiotherapy products, and diagnostic imaging systems, demonstrating expertise in healthcare solutions and a strong reputation for quality in the medical industry.
- X-ray energy levels
- 6MV,10MV,15MV
- Electron energy range
- 6 MeV to 21 MeV
- Jaw collimator system
- Dual independent with dynamic jaw tracking
- Multileaf collimator (MLC) speed
- High speed with 120 leaves
- Treatment table precision
- High precise IGRT with auto correction
- Control system
- Real-time digital
- Console type
- Low flow,integrated controls
- Treatment automation
- Auto field sequencing and treatment delivery
- Imaging system
- KV-CBCT and EPID MV
- Supported radiation therapy techniques
- 3D-CRT,step and shoot,sliding window,SBRT
- IMAT treatment delivery
- High speed
- Intensity mode
- High intensity,high dose rate FFF
- Radiotherapy Modes
- 3D-CRT,step-and-shoot,sliding window,SBRT
- Treatment Delivery
- High speed IMAT
- Automation Level
- Auto field sequencing and treatment delivery
- Jaw Collimation System
- Dual independent with dynamic tracking
- Treatment Table
- High precise IGRT,auto correction
- Energy Levels
- Three X-rays (6MV,10MV,15MV) and multiple electron rays (6 MeV to 21 MeV)
- Imaging System
- KV-CBCT and EPID MV imaging
- Control System
- Real-time digital control
- Intensity Mode
- High intensity,high dose rate FFF mode
- Dynamic Multileaf Collimator
- 120 leaves
- Density/particle size
- 0.5–2.5 g/cm³ / 50–1000 µm
- Discharge Method
- Auto field sequencing
- Control Panel Type
- Integrated controls
- Jaw Collimator System
- Dual independent jaw
- High Speed DMLC
- 120 leaves
- Control panel type
- Real-time digital control system
- Integration possibilities
- IGRT Treatment table,auto correction
- Integration possibilities
- KV-CBCT imaging system
- Integration possibilities
- EPID MV imaging system
- Jaw collimator system
- Dual independent jaw collimator system,dynamic jaw tracking
- IMAT treatment delivery
- High speed IMAT treatment delivery